SDM7-25 MOULDED CASE CIRCUIT BREAKER MPCB

Purchase Qty.:
(Pieces)
100-999 1,000-9,999 10,000+
FOB Unit Price: US $5 US $4.8 US $4.5
Purchase Qty. (Pieces) FOB Unit Price
100-999 US $5
1,000-9,999 US $4.8
10,000+ US $4.5
Get Latest Price
Port: Ningbo, China
Production Capacity: 10000/Month
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
Hot sell product
50 Products
Content
Product Image
Product Name
FOB Price
Port
Basic Info
  • Model NO.: SDM6
  • Operation: Manual Type
  • Arc-extinguishing Medium: Air
  • Structure: Moulded Case Circuit Breaker
  • Type: Circuit Breaker
  • Certification: ISO9001-2000, CE, CB, CCC
  • Rated Voltage: 220/380V
  • Rated Frequency: 50/60Hz
  • Transport Package: Sea Worthy, Neutral, Customer Defined.
  • Origin: Wenzhou, China
  • Breaking Capacity: Low Voltage Circuit Breakers
  • Speed: Normal Type Circuit Breaker
  • Installation: Fixed
  • Poles Number: 3
  • Function: Overload, Undervoltage, Short-Circuit
  • Poles: 3p/4p
  • Rated Current: 0.1-32A
  • Trademark: SAIDE
  • Specification: CE, Rohs
  • HS Code: 8536200
Product Description
1. Application Area
SDM7-25 series moulded case circuit breaker mainly applies to power systems of AC690V, 50Hz, rated current ranged from 0.1~32A, its purpose lays in protection against overload, phase defect, short-circuit, etc. under 3-phase rotor cage induction motor system, it also can work as infrequent ON/OFF switch and isolator.
SDM7-25 approves CCC, CE, TSE certificate.

2. Working Circumstance
2.1 Altitude of the install place shall not be higher than 2000m.
2.2 Circumstance temperature shouldn't be higher than +40ºC, or lower than -5ºC.
2.3 Relative humidity shall not be higher than 50% when temperature at the highest +40ºC. Average humidity of the most humid month shall not exceed 90%, while average temperature of this month shall not be lower than 25ºC.  
2.4 Pollution class: 3.
2.5 Install type: II, III(load class & distributing class)
2.6 Inclination between install plane surface and vertical plane surface shall not exceed ±5°.
2.7 Working system: uninterrupted type.

3. Working Theory & Structure Characteristics
SDM7-25 circuit breaker is an integrated equipment which includes the functions of isolator, breaker, thermal relay, etc. it can effectively protect power system from malfunctions as overload, phase defect, temperature compensation, short-circuit, etc.
SDM7-25 circuit breaker complies to GB14048.2, GB14048.4, IEC40947-2, IEC60947-4-1 standards.
SDM7-25 structure: connected to main circuit through thermal components, while motor suffers from overload, the bimetallic strip inside got heated up to trigger the circuit breaker to break off.
When motor suffers from phase defect, the bimetallic strip of this phase would cool down and recover its shape, by differential device's enlarging effect, circuit breaker would break off. While current reach the limit of instantaneous electromagnetic trip, magnetic core acts at once, forcing lever to cut off the current while driving operating module to trip, making circuit breaker to break off.
SDM7-25 breaker is in consist of bottom foundation, contact support, arc-chute, insulating base, thermal-magnetic system(including instantaneous electromagnetic tripping unit, bimetallic strip, thermal components, etc.), differential device, current adjusting device, operating module, product cover, push button and so on.
SDM7-25 breaker adopts flip-over direct-acting type double contacts structure, contact bridge, contact support & arc-chute are installed in the bottom foundation, thermal-magnetic system, static contact, operating module, differential device, current adjusting device are installed on base. There is a breaking test function, toggle the handle inside the "test" column according to the printed arrow to make sure the overload tripping function is reliable.

4. Technical Data
 
Rated Current/In(A)Adjustable Current Range (A)Rated Ultimate Short-circuit Breaking Capacity(Icu)   Rated Working Short-circuit Breaking Capacity(Ics)Lifespan
230/240V400/415V440V500V690VArc DistanceMechanicElectric
Icu(kA)Ics(kA)Icu(kA)Ics(kA)Icu(kA)Ics(kA)Icu(kA)Ics(kA)Icu(kA)Ics(kA)
0.160.1-0.1610010010010010010010010010010050mm200002000
0.250.16-0.25100100100100100100100100100100
0.40.25-0.4100100100100100100100100100100
0.630.4-0.63100100100100100100100100100100
10.63-1100100100100100100100100100100
1.61-1.6100100100100100100100100100100
2.51.6-2.510010010010010010010010032
42.5-410010010010010010010010032
6.34-6.31001001001005050505032
106-101001001001001510101032
149-1410010062626232
1813-1810010062626232
2317-23505062626232
2520-25505062626232
3224-32505062626232
4.1 Rated insulation voltage Ui(V): 690
4.2 Rated impulse withstanding voltage Uimp(kV): 6
4.3 Rated working voltage Ue(V): 230(240), 400(415), 440, 500, 690
4.4 Rated frequency (Hz): 50
4.5 Structural level rated current Inm(A): 32
5.Catalog

SDM7-25 MOULDED CASE CIRCUIT BREAKER MPCB


About Our factory
SDM7-25 MOULDED CASE CIRCUIT BREAKER MPCBSDM7-25 MOULDED CASE CIRCUIT BREAKER MPCB

CHINA * SAIDE ELECTRIC CO.,LTD

Address : Qiligang industrial Zone ,Liushi,Yueqing ,Zhejiang,China

Tel:0086-577-62755267

Phone:18657700751

Send your message to this supplier
Avatar
Ms. Joyce Chen
Manager
*From:
To: Ms. Joyce Chen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category